 Model220V=10.1W
 110V=61.4W220V=13.42W
 110V=85.19WКоммутатор Cisco SG250-10P-K9-EU 
● 8 10/100/1000 PoE+ ports with 62W power budget
● 2 Gigabit copper/SFP combo ports with 60W PoE power input support
									● 8 10/100/1000 PoE+ ports with 62W power budget
● 2 Gigabit copper/SFP combo ports with 60W PoE power input support
Технические характеристики
(worst case)
 Model220V=10.1W
 110V=61.4W220V=13.42W
 110V=85.19W220V=133.9W
 461.32220V=230W
 812.09220V=24.4W
 110V=135.2W220V=254.5W
 893.98220V=255.8W
 904.90220V=257.1W
 887.50220V=263.5W
 911.72220V=28.3W
 110V=238W220V=37.2W
 110V=262W220V=44.3W
 110V=265.2W220V=468.1W
 1,644.31220V=487.1W
 1,713.92220V=49.2W
 110V=260.1W220V=59.3W
 110V=267.2W220V=59.8W
 209.51220V=60.3W
 110V=481.9W220V=70.3W
 110V=502.3W220V=84.17W
 290.684 10 Gigabit Ethernet
 48 Gigabit Ethernet4 Gigabit Ethernet
 48 Fast Ethernet50°C 44.9dB
 130,25550°C 46.2dB
 62,94950°C 47.3dB
 62,60750°C 47.5dB
 134,93350°C 49.3dB
 68,58550°C 49.7dB
 333,79250°C 50.2dB
 53,83950°C 50.6dB
 53,72250°C 52.2dB
 314,04050°C 52.7dB
 286,55550°C 53.7dB
 430,341802.3at PoE+ and 802.3af PoE delivered over any of the RJ-45 por
 The following switches support 802.3at PoE+, 802.3af, and Cisco prestandard (legacy) PoE. Maximum power of 30.0W to any 10/100 or Gigabit Ethernet port, until the PoE budget for the switch is reached. The total power available for PoE per switch is as followsAC Power
 YesAccess Control Lists (ACLs)
 Support for up to 512 rulesAcoustic noise and Mean Time Between Failures (MTBF)
 Model nameAuto Smartports
 Automatically applies the intelligence delivered through the Smartports roles to the port based on the devices discovered over Cisco Discovery Protocol or LLDP-MED. This facilitates zero-touch deploymentsAutoconfiguration with SCP file download
 Enables mass deployment with protection of sensitive dataBonjour
 The switch advertises itself using the Bonjour protocolButtons
 Reset buttonCable length detection
 Adjusts the signal strength based on the cable length. Reduces the power consumption for shorter cablesCabling Type
 Unshielded Twisted Pair (UTP) Category 5 or better for 10BASE-T/100BASE-TX; UTP Category 5e or better for 1000BASE-TCertification
 UL (UL 60950), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class ACisco Discovery Protocol
 The switch advertises itself using the Cisco Discovery Protocol. It also learns the connected device and its characteristics using Cisco Discovery ProtocolCisco Network Plug and Play (PnP) agent
 The Cisco Network Plug and Play solution provides a simple, secure, unified, and integrated offering to ease new branch or campus device rollouts or for provisioning updates to an existing network. The solution provides a unified approach to provision Cisco routers, switches, and wireless devices with a near-zero-touch deployment experienceClass of service
 Port based; 802.1p VLAN priority based; IPv4/v6 IP precedence/Type of Service (ToS)/DSCP based; Differentiated Services (DiffServ); classification and re-marking ACLs, trusted QoSClassless Interdomain Routing (CIDR)
 Support for CIDRCloud services
 Support for Cisco FindIT Network Manager and Cisco Active AdvisorCongestion avoidance
 A TCP congestion avoidance algorithm is required to reduce and prevent global TCP loss synchronizationCPU
 800 MHz ARMCPU memory
 512 MBDHCP relay at Layer 3
 Relay of DHCP traffic across IP domainsDisable port LEDs
 LEDs can be manually turned off to save on energyDoS prevention
 Denial-of-Service (DoS) attack preventionDynamic Host Configuration Protocol (DHCP) (options 12, 66, 67, 
 DHCP options facilitate tighter control from a central point (DHCP server), to obtain IP address, autoconfiguration (with configuration file download), DHCP Relay, and host nameEEE compliant (802.3az)
 Supports IEEE 802.3az on all copper Gigabit Ethernet portsEmbedded FindIT Network Probe
 Support for embedded FindIT Network Probe running on the switch. Eliminates the need to set up a separate hardware or virtual machine for the FindIT Network Probe on siteEnergy detect
 Automatically turns power off on RJ-45 port when detecting link down. Active mode is resumed without loss of any packets when the switch detects the link is upFeature
 DescriptionFirmware upgrade
 Web browser upgrade (HTTP/HTTPS) and TFTP and upgrade over SCP running over SSHFlash
 256 MBGeneric VLAN Registration Protocol (GVRP)and Generic Attribute R
 Protocols for automatically propagating and configuring VLANs in a bridged domainGLC-BX-U=
 1000 MbpsHOL blocking
 Head-Of-Line (HOL) blockingIEEE 802.1X (authenticator role)
 RADIUS authentication, guest VLAN, single/multiple host mode, and single/multiple sessionsIGMP (versions 1, 2, and 3) snooping
 Internet Group Management Protocol (IGMP) limits bandwidth-intensive multicast traffic to only the requesters; supports 4K multicast groups (source-specific multicasting is also supported)IGMP querier
 Used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast routerIPv4 and IPv6 dual stack
 Coexistence of both protocol stacks to ease migrationIPv4 Routing
 Wire-speed routing of IPv4 packetsIPv6
 IPv6 host modeIPv6 ACL
 Drop or rate limit IPv6 packets in hardwareIPv6 applications
 Web/SSL, Telnet server/SSH, Ping, Traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), Simple Network Management Protocol (SNMP), Remote Authentication Dial-In User Service (RADIUS), Syslog, DNS client, DHCP client, DHCP autoconfigIPv6 QoS
 Prioritize IPv6 packets in hardwareIPv6 RFCs supported
 RFC 4443 (which obsoletes RFC 2463) ICMPv6IPv6 routing
 Wire-speed routing of IPv6 packetsJumbo frames
 Frame sizes up to 9K bytes. The default MTU is 2K bytesLayer 3 interface
 Configuration of Layer 3 interface on physical port, LAG, VLAN interface, or loopback interfaceLEDs
 System, Link/Act, PoE, SpeedLink Layer Discovery Protocol (LLDP) (802.1ab) with LLDP-MED ext
 Link Layer Discovery Protocol (LLDP) allows the switch to advertise its identification, configuration, and capabilities to neighboring devices that store the data in a MIB. LLDP-MED is an enhancement to LLDP that adds the extensions needed for IP phonesLocalization
 Localization of GUI and documentation into multiple languagesLogin banner
 Configurable multiple banners for web as well as CLILoopback detection
 Provides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STPMAC table
 8K addressesModel
 Power optionMulticast Listener Discovery (MLD v1/2) snooping
 Deliver IPv6 multicast packets only to the required receiversOperating temperature
 32° to 122°F (0° to 50°C)Other management
 Traceroute; single IP management; HTTP/HTTPS; RADIUS; port mirroring; TFTP upgrade; DHCP client; Simple Network Time Protocol (SNTP); cable diagnostics; Ping; syslog; Telnet client (SSH secure support); automatic time settings from Management StationPacket buffer
 All numbers are aggregate across all ports because the buffers are dynamically sharedPoE Powered Device (PD) and PoE pass-through
 Besides AC power, select compact switch models can work as PoE Powered Device (PD) and be powered by PoE switches connected to the uplink ports. The switch can also pass through the power to downstream PoE end devices if requiredPort grouping/link aggregation
 Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP)Port mirroring
 Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe. Up to 4 source ports can be mirrored to one destination portPort security
 Ability to lock source MAC addresses to ports and limit the number of learned MAC addressesPower
 100 to 240V 50 to 60 Hz, internal, universal SF250-24, SF250-24P, SF250-48, SF250-48HP, SG250-26, SG250-26HP, SG250-26P, SG250-50, SG250-50HP, SG250-50P, SG250X-24, SG250X-24P, SG250X-48, SG250X-48PPriority levels
 8 hardware queuesPrivate MIBs
 CISCOSB-lldp-MIBRADIUS
 Supports RADIUS authentication for management access. Switch functions as a clientRate limiting
 Ingress policer; egress shaping and rate control; per VLAN, per port, and flow basedRemote monitoring (RMON)
 Embedded RMON software agent supports 4 RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysisScheduling
 Strict priority and Weighted Round-Robin (WRR) queue assignment based on DSCP and class of service (802.1p/CoS)Secure Copy (SCP)
 Securely transfers files to and from the switchSecure Core Technology (SCT)
 Ensures that the switch will receive and process management and protocol traffic no matter how much traffic is receivedSecure Sensitive Data (SSD)
 A mechanism to manage sensitive data (such as passwords, keys, and so on) securely on the switch, populating this data to other devices, and secure autoconfig. Access to view the sensitive data as plaintext or encrypted is provided according to the user-configured access level and the access method of the userSecure Shell (SSH) Protocol
 SSH is a secure replacement for Telnet traffic. Secure Copy (SCP) also uses SSH. SSH v1 and v2 are supportedSF250-24P
 0° to 25°C 39.7dBSF250-48HP
 0° to 30°C 38.0dBSFP-10G-LR-S
 10 GigSG250-08HP
 8 Gigabit EthernetSG250-10P
 10 Gigabit EthernetSG250-18
 18 Gigabit EthernetSG250-26
 –SG250-26HP
 0° to 30°C 37.5dBSG250-26P
 0° to 30°C 36.0dBSG250-50HP
 0° to 30°C 34.2dBSG250-50P
 0° to 30°C 35.6dBSG250X-24
 0° to 30°C 32.6dBSG250X-24P
 0° to 30°C 35.1dBSG250X-48
 0° to 30°C 36.6dBSG250X-48P
 0° to 30°C 35.9dBSmart Network Application (SNA)
 An innovative network-level monitoring and management tool embedded in Cisco 250 to 550X Series switches. It can discover network topology, display link status, monitor events, apply configurations, and upgrade software images across multiple switches in the networkSmartports
 Simplified configuration of QoS and security capabilitiesSNMP
 SNMP versions 1, 2c, and 3 with support for traps, and SNMP v3 User-based Security Model (USM)Spanning Tree Protocol (STP)
 Standard 802.1d spanning tree supportSSL
 Secure Sockets Layer (SSL) encrypts all HTTPS traffic, allowing secure access to the browser-based management GUI in the switchStandard MIBs
 lldp-MIBStandards
 IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, IEEE 802.3 ad LACP, IEEE 802.1D (STP), IEEE 802.1Q/p VLAN, IEEE 802.1w RSTP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793, RFC 813, RFC 879, RFC 896, RFC 826, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC 919, RFC 920, RFC 922, RFC 950, RFC 951, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1213, RFC 1215, RFC 1286, RFC 1350, RFC 1442, RFC 1451, RFC 1493, RFC 1533, RFC 1541, RFC 1542, RFC 1573, RFC 1624, RFC 1643, RFC 1700, RFC 1757, RFC 1867, RFC 1907, RFC 2011, RFC 2012, RFC 2013, RFC 2030, RFC 2131, RFC 2132, RFC 2233, RFC 2576, RFC 2616, RFC 2618, RFC 2665, RFC 2666, RFC 2674, RFC 2737, RFC 2819, RFC 2863, RFC 3164, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 3416, RFC 4330Storage humidity
 10% to 90%, relative, noncondensingStorage Temperature
 -4° to 158°F (-20° to 70°C)Storm Control
 Broadcast, multicast, and unknown unicastSTP loopback guard
 Provides additional protection against Layer 2 forwarding loops (STP loops)Supported SFP/SFP+ modules
 SKUText-editable configs
 Config files can be edited with a text editor and downloaded to another switch, facilitating easier mass deploymentTextview Command-Line Interface (CLI)
 Scriptable CLI. A full CLI as well as a menu-based CLI is supported. User privilege levels 1, 7, and 15 are supported for the CLITime-based PoE
 PoE power can be on or off based on user-defined schedule to save energyTime-based port operation
 Link up or down based on user-defined schedule (when the port is administratively up)USB slot
 USB Type-A slot on the front panel of the switch for easy file and image managementUser Datagram Protocol (UDP) relay
 Relay of broadcast information across Layer 3 domains for application discovery or relaying of bootP/DHCP packetsVLAN
 Support for up to 256 active VLANs simultaneouslyVLAN mirroring
 Traffic from a VLAN can be mirrored to a port for analysis with a network analyzer or RMON probe. Up to 4 source VLANs can be mirrored to one destination portVoice VLAN
 Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoS. Auto voice capabilities deliver networkwide zero-touch deployment of voice endpoints and call control devicesWarranty
 Limited lifetimeWeb user interface
 Built-in switch configuration utility for easy browser-based device configuration (HTTP/HTTPS). Supports configuration, wizards, system dashboard, system maintenance, and monitoringОтзывов: 0
							
							
							